Troubleshooting guide for ERO joint® WT wide timing belts

ProblemProbable causeCorrective action

Junction fracture

Too heavy a load

Request a reinforced 5-rod joint

Junction fracture

Accident or wear and tear

End finger spacing

Voltage too high

Reducing tension

End finger spacing

Direction of travel error

Check direction of travel

End finger spacing

Failure to use the lubricant/glue supplied

Migration of stems to edges

Return to service too quickly after installation (without lubricant/adhesive drying out)

Migration of stems to edges

High band constraints

Use toothed rods instead of healds